TROUBLESHOOTING (cont.)

REMEDY

(A) The circuit breaker must not be
tripped.

(B) Refer to

Service

- Circuit Breaker

for testing procedures. See page 27.

Remove the lamps and check for
continuity across the base and tip.
Replace if necessary.

Refer to

Service

- Transformer for

testing procedures. See page 49.

Refer to

Service

- Lamp Holder/

Socket Assembly for testing proce-
dures. See page 44.

(A) The auger switch must be in the
"ON" position.

(B) Refer to

Service

- Auger ON/OFF

Switch(es) for testing procedures.
See page 26.

Refer to

Service

- Auger Motor

Capacitor(s) for testing procedures.
See page 23.

Refer to

Service

- Auger Motor(s) for

testing procedures. See page 22.

Refer to

Service

- Fan Motor for

testing procedures. See page 39.

The fan motor will run for approxi-
mately two minutes after compres-
sor shuts off.

PROBABLE CAUSE

3. Circuit Breaker

4. Lamps

5.Transformer

6. Lamp Holder/Socket Assy

1. Auger ON/OFF Switch(es)

2. Auger Motor Capacitor(s)

3. Auger Motor(s)

1. Fan Motor

1. Time Delay

PROBLEM

Hopper Display Lights not on (cont.)

Auger Motor won't turn

Fan not spinning (With adjustment
Board L.E.D.s ON steadily for two
minutes)

Fan spins after compressor shuts
off