Bunn CDS-3 User Manual

Page 29

Advertising
background image

29

SERVICE (cont.)

COMPRESSOR & COMPONENTS (CDS-2) (cont.)

Compressor Start Capacitor:
1. Check for continuity across the terminals on the

compressor start capacitor.

If continuity is present as described, the start capaci-
tor is operating properly.

If continuity is not present as described, replace the
capacitor.

NOTE: If all the electrical components are operating prop-
erly and the compressor does not operate, there is an
internal mechanical problem. Replace the compressor.

Removal and Replacement:

Compressor Assy:

NOTE: Before removal of any refrigeration component
the refrigerant in the system must be reclaimed by a
licensed refrigeration repair person.
1. Disconnect the tubes from the condenser and the

accumulator.

2. Disconnect the compressor wiring harness from

the dispenser main wiring harness.

3. Remove the four .25-20 keps nuts and washers

securing the compressor to the chassis. Set nuts
and washers aside for reassembly.

4. Remove the four #8-32 locking screws securing

the component bracket to the dispenser chassis.

5. Disconnect the wires from the circuit breaker, fuse

holder, transformer, electronic control and the
contactor.

6. Remove component bracket with circuit breaker,

fuse holder, transformer, electronic control and
contactor as an assembly. Set component bracket
and screws aside for reassembly.

7. From the right side of the dispenser lift the com-

pressor assembly over the four studs in the chas-
sis and remove compressor.

8. Install new compressor over the four studs in the

dispenser chassis with the fill valve to the left side
of the dispenser.

9. Secure compressor to the dispenser chassis using

four .25-20 keps nuts and washers.

10. Reconnect the wires to the components on the

component bracket and plug the main wiring har-
ness into the electronic control.

NOTE: When reconnecting wires refer to Fig. 10 for
circuit breaker, Fig. 34 for fuse holder, Fig. 51 for trans-

former and Fig. 22 for contactor.
11. Position the component bracket in the chassis and

secure with four #8-32 locking screws.

12. Reconnect tubes from the condenser and the

accumulator to the compressor.

13. Evacuate the system.

NOTE: When replacing the compressor it is recom-
mended that the dryer also be replaced.
14. Recharge 120V system with 8.4 oz. of Type R22

refrigerant. Design Pressures: High 210 - Low 32
Recharge 230V system with 9.5 oz. of Type 404A
refrigerant. Design Pressures: High 215 - Low 40

NOTE: The charging of the system must be done by a
licensed refrigeration repair person.

Compressor Start Capacitor: Refer to FIG. 12

WARNING: The compressor start capacitor must be
properly discharged before proceeding.
1. Remove terminal cover retainer (6) and terminal

cover (5). Set aside for reassembly.

2. Disconnect the two leads from the capacitor.
3. Pry the end of the capacitor mounting bracket off of

the boss on the capacitor and remove the capacitor.

4. Install new capacitor on the capacitor mounting

bracket.

5. Refer to Fig. 13 and reconnect the wires to the

capacitor.

6. Reinstall terminal cover (5) and cover retainer (6).

FIG. 13 COMPRESSOR START CAPACITOR

TERMINALS

P1340

120V DISPENSERS

230V DISPENSERS

27646 122200

Advertising
This manual is related to the following products: