SERVICE (cont.)

LAMP CORD ASSY

FIG. 37 LAMP CORD ASSY

P1343

Location:

The lamp cord assembly is located in the left top of

the auger motor cover.

Test Procedures:
1. Disconnect the dispenser from the power source.
2. Unplug the lamp cord assembly from lamp cord

connector assembly.

3. Check for continuity across the tip of the cord

assembly and the housing. Continuity must not be
present when both lamps are removed.

If continuity is present as described, the cord assem-
bly is operating properly.

If continuity is not present as described, replace the
cord assembly.

Removal and Replacement:
1. Disconnect the lamp cord assembly from the lamp

cord connector assembly in the top of the auger
motor cover.

2. Remove the hopper cover with the lamp cord

assembly from the hopper.

3. Remove hopper cover liner from the hopper cover.
4. Cut the closed splice terminals connecting lamp

cord assembly to the lamp holder/socket assem-
bly off.

5. Remove lamp cord assembly from hopper cover

and discard.

6. Push new lamp cord wires through the holes on

the left outside top of the hopper cover.

7. Strip the wires from the lamp holder/socket as-

sembly approximately .375”.

8. Using the two wire nuts, supplied, connect the new

lamp cord assembly to the lamp holder/socket
assembly wires.

9. Reinstall the hopper liner to the bottom of the

hopper cover.

10. Reinstall the hopper cover to the hopper.
11. Plug in the new lamp cord assembly to the lamp

cord connector assembly on left top of the auger
motor cover.

12. Refer to Fig. 38 when reconnecting the wires.

FIG. 38 LAMP CORD WIRES

P1332

27646 122200