Unit s, c onv er sion f act or s and t abl es – Roxul Industrial Insulation Process User Manual

Page 134

Advertising
background image

Unit

s, c

onv

er

sion f

act

or

s and t

abl

es

Symbol

Definition

US Unit

Notes

R

Thermal resistance

hr.ft

2

.°F/BTU

linear orientation

hr.ft.°F/BTU

cylindrical orientation

hr.°F/BTU

spherical orientation

r

Thermal resistivity

hr.ft

2

.°F/BTU-in

(conventional unit)

hr.ft.°F/BTU

(alternative)

r

a

Apparent thermal resistivity

hr.ft

2

.°F/BTU-in

-

Heat Energy

BTU

Q

Heat Flow Rate

BTU/hr

q

Heat Flux

BTU/hr.ft

2

T

Temperature

°R or °F

T

s

Absolute Surface Temperature (Rankine)

°R

T

o

Absolute surroundings temperature (Rankine)

°R

i

inner boundary layer

-

subscript

o

outer boundary layer

-

subscript

s

surface

-

subscript

1 … n

internal layer

-

subscript

131