3.1 Units, conversion factors and tables

3.1.13 Conversion of pressure scales

3.1.14 Conversion of SI-units into Imperial units, pre-SI units and technical scales

Unit

Pascal

(Pa)

Bar

atm

lb/sq ft

lb/sq in.

Pascal (Pa)

10

-5

9.869 * 10

-6

0.201

1.450 * 10

-4

Bar

10

5

0.987

2088.5

13.50

atm

101325

1.013

2116.2

14.70

lb/sq ft.

47.88

4.788 * 10

-4

4.723 * 10

-4

6.944 * 10

-3

lb/sq in.

6894.8

0.0689

0.0680

144.00

Symbol

Quantity

SI-Unit

Technical scales

Imperials units

Q

Heat. energy

J

kcal = 4186.8 J

1 BTU = 1055.06 J

Q

Energy. heat flux

W/m

2

kcal = 1.163 W

m

2

h

m

2

1 BTU

= 3.1546

W

(sq.ft.hr.)

λ

Thermal conductivity

W/(m K)

kcal

= 1.163

W

m

2

h

(m K)

1 BTU

= 1.7307

W

(ft.hr.°F)

(m K)

1 BTU in

= 0.1442

W

(sq.ft.hr.°F)

(m K)

1 BTU

= 20.7688

W

(in.hr.°F)

(m K)

R

Heat resistivity coefficient (R-value)

m

2

K/W

1 m² h

K

= 0.86 m²

K

kcal

W

1 sq.ft.hr.°F = 0.1761 m

2

K

BTU

W

α

Heat transfer coefficient

W/(m

2

K)

kcal

= 1.163

W

(m² h K)

(m

2

K)

1 BTU

= 5.6783

W

(sq.ft.hr.°F)

(m

2

K)

Cp

specific heat capacity

kJ/(kg K)

kcal

= 4.1868

kJ

(kg K)

kg K

1 BTU

= 4.1868

kJ

(lb. °F)

(kg K)

C

Radiant coefficient

W/(m

2

K

4

)

kcal

= 1.63

W

(m

2

h K

4

)

(m

2

K

4

)

1 BTU

= 33.156

kJ

(sq.ft.hr.°R

4

)

(m

2

K

4

)

144