Temperature range in °F

120 to 210

300 to 575

750 to 930

Equivalent length in (ft)

1

Flanges for pressure stages PN 25 to PN 100

1.1

Uninsulated for pipes

1.1.1

In buildings 70 °F
NPS 2

10 - 16

16 - 36

30 - 49

NPS 4

13 - 23

23 - 52

43 - 52

NPS 6

13 - 30

23 - 56

56 - 98

NPS 8

16 - 36

33 - 85

66 - 121

NPS 12

20 - 52

39 - 121

82 - 187

1.1.2

In the open air 32 °F
NPS 2

23 - 36

30 - 52

39 - 62

NPS 4

30 - 46

43 - 75

59 - 92

NPS 6

36 - 59

46 - 95

72 - 121

NPS 8

43 - 79

59 - 125

89 - 151

NPS 12

52 - 105

69 - 177

105 - 226

NPS 16

72 - 102

92 - 174

144 - 223

NPS 20

82 - 105

102 - 171

157 - 226

1.2

Insulated in buildings 70 °F and in the open air 32 °F for pipes
NPS 2

2.3 - 3.3

2.3 - 3.3

3.3 - 3.6

NPS 4

0.3 - 3.3

2.6 - 3.9

3.6 - 4.6

NPS 6

2.6 - 3.6

2.6 - 4.3

4.3 - 5.2

NPS 8

2.6 - 4.3

3 - 4.6

4.3 - 5.6

NPS 12

2.6 - 4.6

3.3 - 5.2

4.6 - 6.2

NPS 16

3.3 - 4.6

3.6 - 5.2

5.2 - 6.2

NPS 20

3.6 - 4.3

3.6 - 5.2

5.2 - 5.9

2

Fittings for pressure stages PN 25 to PN 100

2.1

Uninsulated for pipes

2.1.1

In buildings 70 °F
NPS 2

30 - 49

52 - 95

89 - 128

NPS 4

49 - 69

79 - 151

138 - 207

NPS 6

52 - 92

85 - 207

190 - 295

NPS 8

69 - 115

121 - 269

240 - 354

NPS 12

95 - 167

164 - 381

348 - 581

NPS 16

118 - 197

194 - 446

413 - 676

NPS 20

151 - 249

246 - 558

518 - 876

3.3.11 Equivalent pipe length for flanges & valves

Reference values for plant related thermal bridges (table A14 - VDI 2055)

3.3 Usage tables

164