Installation, Regency, Direct vent flex system – Regency Panorama P33E Small Gas Fireplace User Manual

Page 18

Advertising
background image

18

Regency® P33E-4 Zero Clearance Direct Vent Gas Fireplace

INSTALLATION

Wherever necessary due to
external location of cap, the
AstroCap can be replaced with
the FPI Riser Vent Termination
Cap or the Dura-Vent Snorkel
Termination Cap.

REGENCY

®

DIRECT VENT FLEX SYSTEM

Horizontal Terminations Only

This venting system, in combination with the P33E-4 Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system by Warnock Hersey/

Intertek. The location of the termination cap must conform to the requirements in the "Exterior Vent Terminal Locations" Section .

Regency

®

Direct Vent Flex Termination Kit (Part # 946-513) includes all the parts needed to install the P33E-4 with a maximum run of 2 feet. If install-

ing the P33E with a continuous vent length of more than 2 ft (.6m) to a maximum of 10 ft. (3.0m) use Kit # 946-515 (4 ft) or 946-516 (10 ft) or see "Rigid Pipe

Venting Systems" Section for alternate venting arrangements.

1) 6-7/8"

dia.

fl exible liner (2 ft. length)

2) 4"

dia.

fl exible liner (2 ft. length)

3) spring spacers (3)

4) thimble

(2)

5) AstroCap termination cap (1)

6) screws

(12)

7) tube of Mill Pac (1)

8) plated screws (8)

9) screws #8 x 1-1/2" drill point,

stainless steel (4)

6-7/8"

(173mm)

dia. Flue pipe

4" (102mm)

dia. flue pipe

Wall Thimble (2 pc)

(required in

Canada only)

Termination Cap

(Part# 946-523/P)

AstroCap

TM

spring
spacer

See Figure 1 below for

Alternate Caps.

Notes:
1) Liner sections should be continuous

without any joints or seams.

2) Only Flex pipe purchased from Regency

®

may be used for Flex installations.

MINIMUM

FLEX KIT CENTER-LINE

MINIMUM

RIGID PIPE CENTER-LINE

Alternate

Horizontal

Termination

Caps

Note: for P33E-NG4 with contemporary faceplate - unit must be raised by 1".

Figure 1