Installation, Standard flush door, Optional flush trim – Regency Panorama P33E Small Gas Fireplace User Manual

Page 37

Advertising
background image

Regency® P33E-4 Zero Clearance Direct Vent Gas Fireplace

37

INSTALLATION

Diagram 1

Diagram 3

STANDARD FLUSH

DOOR

The standard fl ush door comes with a black
frame. To install the frame, simply hook the top
door fl ange onto the top of the unit and swing
the door towards the unit, diagram 1. Be careful
that the glass gasket does not roll up; there must
be a gap between the gasket and the door lip to
ensure that the door sits securely on the unit.
See Diagram 2.

Diagram 2

5th Grate Tab

6) Place the bottom left front edge of Log 251

against the left edge of the burner tray and
rest the log on the cutout on Log 253.

7) Position Log 252 across the cutouts in Logs

254 and 253. The notch in the bottom right
end fi tting against the 5th grate tab.

8) Pull off ember size pieces of rock wool and

gently place them on the front of the burner
tray in the places shown in the photo below.
Do not compress the rock wool, leave it
loose.

Separate platinum embers and place them
on the front of the burner on and around the
rock wool.

Place rock wool in these 2 locations

on the burner tray.

251

252

250

254

253

250

254

253

251

253

250

254

253

254

252

Cutout

9) Test fi re to ensure proper light off (make

sure fl ame fl ows smoothly from one end of
burner to the other). If there is any fl ame
hesitation, check that area for any blockage
of the burner ports.

Use the hook to pull the spring out until you
can put the hook into the slot on the bottom
door bracket. Repeat for 2nd spring. See
diagram 3.

To remove the fl ush door, reverse the above
steps.

OPTIONAL FLUSH

TRIM

Attach the round magnets to the back of the
top trim piece and to the bottom trim piece,
then attach trim to the top and bottom of
Flush door.

Advertising