Installation, Rigid pipe venting arrangements, Horizontal terminations regency – Regency Panorama P33E Small Gas Fireplace User Manual

Page 25: Direct vent system (flex) (propane & natural gas)

Advertising
background image

Regency® P33E-4 Zero Clearance Direct Vent Gas Fireplace

25

INSTALLATION

RIGID PIPE VENTING ARRANGEMENTS

Horizontal Terminations

REGENCY

®

DIRECT VENT SYSTEM (FLEX)

(Propane & Natural Gas)

This diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 45

o

and one 90

o

elbow (two 45

o

elbows equal one 90

o

elbow).

Note: Must use optional rigid pipe adaptor (Part # 510-994) when using rigid pipe vent systems. (Refer "Rigid Pipe Venting Systems" Section)

• Maintain clearances to combustibles.
• Horizontal vent must be supported every 3 feet.
• Firestops are required at each fl oor level and whenever passing through a wall.
• When using Contemporary Faceplate, unit must be raised 1".

A vent guard should be used whenever the
termination is lower than the specifi ed minimum
or as per local codes.

Note: Regency

®

Direct Vent System (Flex)

is only approved for horizontal
terminations.

Minimum

Simpson Dura-Vent Center-Line

Minimum

Flex Kit Center-Line