Regency® P33E-4 Zero Clearance Direct Vent Gas Fireplace

INSTALLATION

Vertical Venting with Three (3) 90

o

Elbows

Vertical Venting with Three (3) 90

o

Elbows

Option

H

V

H + H1 V + V1

A)

1' Max. 1' Min. 3' Max. 3' Min.

B)

2' Max. 2' Min. 4' Max. 5' Min.

C)

3' Max. 3' Min.' 5' Max. 7' Min.

D)

4' Max. 4' Min. 6' Max. 9' Min.

E)

5' Max. 5' Min. 7' Max. 11' Min.

One 90

o

elbow = Two 45

o

elbows.

One 90

o

elbow = Two 45

o

elbows.

With these options, max. total
pipe length is 30 feet with min.
of 11 feet total vertical and
max. 7 feet total horizontal.
Please note min. 1 foot
between 90

o

elbows is

required.

Option V

H + H1 V + V1

A)

2' Min. 3' Max. 4' Min.

B)

3' Min. 4' Max. 6' Min.

C)

4' Min. 5' Max. 7' Min.

D)

5' Min. 6' Max. 8' Min.

E)

6' Min. 7' Max. 9' Min.

F)

7' Min. 8' Max. 10' Min.

With these options, max.
total pipe length is 30 feet
with min. of 10 feet total
vertical and max. 8 feet total
horizontal.
Please note min. 1 foot
between 90

o

elbows is

required.