Installation, Important message, Before you start – Regency Panorama P33E Small Gas Fireplace User Manual

Page 7: General safety information, Manufactured mobile home additional requirements

Advertising
background image

Regency® P33E-4 Zero Clearance Direct Vent Gas Fireplace

7

INSTALLATION

IMPORTANT MESSAGE

SAVE THESE

INSTRUCTIONS

The P33E-NG4 or P33E-LP4 Direct Vent Fireplace
must be installed in accordance with these
instructions. Carefully read all the instructions in
this manual fi rst. Consult the "authority having
jurisdiction" to determine the need for a permit prior
to starting the installation. It is the responsibility of
the installer to ensure this fi replace is installed in
compliance with manufacturer's instructions and all
applicable codes.

BEFORE YOU START

Safe installation and operation of this appliance
requires common sense, however, we are required
by the Canadian Safety Standards and ANSI
Standards to make you aware of the following:

GENERAL SAFETY

INFORMATION

1) The appliance installation must conform with

local codes or, in the absence of local codes,

with the current Canadian or National Gas

Codes, CAN1-B149 or ANSI Z223.1 Installa-

tion Codes.

2) The appliance when installed, must be electri-

cally grounded in accordance with local codes,

or in the absence of local codes with the current

National Electrical Code, ANSI/NFPA 70 or CSA

C22.1 Canadian Electrical Code.

3) See general construction and assembly in-

structions. The appliance and vent should be

enclosed.

4) This appliance must be connected to the speci-

fi ed vent and termination cap to the outside of

the building envelope. Never vent to another

room or inside a building. Make sure that the

vent is fi tted as per Venting instructions.

5) Inspect the venting system annually for blockage

and any signs of deterioration.

6) Venting terminals shall not be recessed into a wall or

siding.

7) Any safety glass removed for servicing must

be replaced prior to operating the appliance.

8) To prevent injury, do not allow anyone who is

unfamiliar with the operation to use the fi replace.

9) Wear gloves and safety glasses for protection

while doing required maintenance.

10) Be aware of electrical wiring locations in walls

and ceilings when cutting holes for termination.

11) Under no circumstances should this appliance

be modifi ed. Parts that have to be removed for

servicing should be replaced prior to operating

this appliance.

12) Installation and any repairs to this appliance

should be done by a qualifi ed service person.

A professional service person should be called

to inspect this appliance annually. Make it a

practice to have all of your gas appliances

checked annually.

13) Do not slam shut or strike the glass door.

14) Under no circumstances should any solid fuels

(wood, paper, cardboard, coal, etc.) be used in

this appliance.

15) The appliance area must be kept clear and

free of combustible materials, (gases and other

fl ammable vapours and liquids).

MANUFACTURED

MOBILE HOME

ADDITIONAL

REQUIREMENTS

1) Ensure that structural members are not cut or

weakened during installation.

2) Ensure proper grounding using the #8 ground

lug provided. Refer to "Wiring Diagram" Section.

Emissions from burning wood or gas could
contain chemicals known to the State of
California to cause cancer, birth defects
or other reproductive harm.

CHILDREN AND ADULTS SHOULD BE
ALERTED TO THE HAZARDS OF HIGH
SURFACE TEMPERATURES, ESPE-
CIALLY THE FIREPLACE GLASS, AND
SHOULD STAY AWAY TO AVOID BURNS
OR CLOTHING IGNITION.

INSTALLATION AND REPAIR SHOULD
B E D O N E B Y A N AU T H O R I Z E D
SERVICE PERSON. THE APPLIANCE
SHOULD BE INSPECTED BEFORE
USE AND AT LEAST ANNUALLY BY A
PROFESSIONAL SERVICE PERSON.
MORE FREQUENT CLEANING MAY
BE REQUIRED DUE TO EXCESSIVE
LINT FROM CARPETING, BEDDING
MATERIAL, ETC. IT IS IMPERATIVE THAT
CONTROL COMPARTMENTS, BURNERS
AND CIRCULATING AIR PASSAGEWAYS
OF THE APPLIANCE BE KEPT CLEAN.

DUE TO HIGH TEMPERATURES, THE
APPLIANCE SHOULD BE LOCATED
OUT OF TRAFFIC AND AWAY FROM
FURNITURE AND DRAPERIES.

WARNING: FAILURE TO INSTALL THIS
APPLIANCE CORRECTLY WILL VOID
YOUR WARRANTY AND MAY CAUSE A
SERIOUS HOUSE FIRE.

CLOTHING OR OTHER FLAMMABLE
MATERIAL SHOULD NOT BE PLACED
ON OR NEAR THE APPLIANCE.

YOUNG CHILDREN SHOULD BE CARE-
FULLY SUPERVISED WHEN THEY ARE
IN THE SAME AREA AS THE APPLI-
ANCE. TODDLERS, YOUNG CHILDREN
AND OTHERS MAY BE SUSCEPTIBLE
TO ACCIDENTAL CONTACT BURNS. A
PHYSICAL BARRIERS IS RECOMMEND-
ED IF THERE ARE AT RISK INDIVIDUAL
IN THE HOUSE. TO RESTRICT ACCESS
TO A FIREPLACE OR STOVE, INSTALL
AN ADJUSTABLE SAFETY GATE TO
KEEP TODDLERS, YOUNG CHILDREN
AND OTHER AT RISK INDIVIDUALS OUT
OF THE ROOM AND AWAY FROM HOT
SURFACES.

Advertising