Installation, Locating your gas fireplace, Manufactured mobile home additional requirements – Regency Panorama P36E Medium Gas Fireplace User Manual

Page 10: Optional heat release kit

Advertising
background image

P36E-4 Zero Clearance Direct Vent Gas Fireplace

10

HEATWAVE

DUCT SYSTEM

OPTIONAL KIT #946-556

The HeatWave Air Duct Kit increases the
effectiveness of your fi replace by dispersing
warm air from the fi replace to remote locations in
the same room or other rooms in your home.

Up to two kits may be installed on the
fi replace.

Please Note: Only 1 HeatWave kit may be
operated at one time. This includes the internal
blower option as well.

Diagram 1

This includes:

1) Clocking the appliance to ensure the correct

fi ring rate (rate noted on label 29,500 NG
/ 28,500 LP Btu/h) after burning appliance
for 15 minutes.

2) If required, adjusting the primary air to

ensure that the fl ame does not carbon.
First allow the unit to burn for 15-20 min.
to stabilize.

CAUTION:

Any alteration to the product that causes
sooting or carboning that results in
damage is not the responsibility of the
manufacturer.

LOCATING YOUR

GAS FIREPLACE

1) When selecting a location for your fi replace,

ensure that the clearances outlined on this
page are met.

2) Provide adequate clearances for

servicing.

3) The appliance must be installed on a fl at,

solid, continuous surface (e.g. wood, metal,
concrete). This may be the fl oor, or raised up
on a platform to enhance its visual impact.
If the appliance is going to be installed
on carpeting, combustible linoleum tile or
other combustible material other than wood
fl ooring, the appliance must be installed on
a metal or wood panel extending the full
width and depth of the appliance.

4) The P36E Direct Vent Gas Fireplace can be

installed in a recessed position or framed
out into the room as in A, B, C, D. See

Diagram

1.

INSTALLATION

your plans before installation.

Note: For vent terminations see the

" E x t e r i o r Ve n t Te r m i n a t i o n
Locations" section.

MANUFACTURED

MOBILE HOME

ADDITIONAL

REQUIREMENTS

1) Ensure that structural members are not cut

or weakened during installation.

2) Ensure proper grounding using the #8

ground lug provided. See the "Alternate
Wiring Diagram for Wall Switch" section.

5) This appliance is Listed for bedroom

installations when used with a Listed Millivolt
Thermostat. Some areas may have further
requirements, check local codes before
installation.

6) The P36E Direct Vent Gas Fireplace is

approved for alcove installations, which
meet the clearances listed on this page.

7) We recommend that you plan your installation

on paper using exact measurements for
clearances and fl oor protection before
actually installing this appliance. Have a
qualifi ed inspector, dealer, or installer review

A) Flat on Wall
B) Flat on Wall Corner
C) Recessed into Wall/Alcove
D) Corner

Before leaving this unit with the customer,
the installer must ensure that the appliance is
fi ring correctly and operation fully explained
to customer
.

OPTIONAL

HEAT RELEASE KIT

#946-570

The Heat Release Kit expels warm air from
the fi replace to the outside of the building,
allowing the fi replace to be operated with less
heat entering the room. The kit may be used on
either the left or right side.

The HeatWave Duct Kit has different
clearance and framing requirements, check
the HeatWave manual for details.

5) Install standard and optional features. Refer

to the following sections where applicable:


a.

Install 4 AA batteries into battery pack or
optional AC Power Adaptor

b. Optional Brick Panels

c. Log Set Installation

d. Standard Flush Door

e. Regency Flush or Bay Fronts

f. Hampton Cast Faceplate

g. Remote Control

h. Wall Switch

i. Wall Thermostat

j. Fan Installation

6) Final check.