NOTE: Wiring schematics for P36E-4 (120 Volts),
plug-in fan circuit with speed control switch on wall.

Lockwasher

Fan

ground wire

Nut

#8 Ground Lug

(for mobile home)

Star washer

Ground

Green

Neutral

Live

Black

Red

Red

Fan Thermodisc

(normally open)

Ground

ON

OFF

Rotary Speed

Control

120V AC
60 Hz

Fan

P36 E lectrical Connec tion Alternative Sc heme " A" ,

P ower at Stove

Wall J unction Box

*Speed Control
S witch with
lead wires
(Regency)

W ire Nuts

W ire Nuts

14 AWG wire

14 AWG wire

*Wire C lamp

*Receptacle B ox
ins ide stove

*Receptacle

(dedicated us e

by stove fan only)

120 Volts

60 Hz

C opper G round

W hite (Neutral)

B lack (Hot)

~

P36 E lectrical Connec tion Alternative Sc heme " B" ,

P ower at Switch

Wall J unction Box

*Speed Control
S witch with lead wires

W ire Nuts

14 AWG wire

*Wire C lamp

120 Volts

60 Hz C opper G round

W hite (Neutral)

B lack (Hot)

W ire

B lack

W hite

G round

*Receptacle B ox

ins ide stove

~~

*Receptacle

(dedicated us e

by stove fan only)

* = s upplied with fan kit

Other parts are to be s upplied
by electrician or ins taller