Installation, Regency, Series combustible mantel clearances – Regency Panorama P36E Medium Gas Fireplace User Manual

Page 13

Advertising
background image

P36E-4 Zero Clearance Direct Vent Gas Fireplace

13

Drywall

12" Mantel

7 1/2" Mantel

3 1/2"
Mantel

Mantel Clearances with

Flush Glass / Full Screen Doors

14"

7"

10"

30-1/2"

to floor

2

0

12

6

4

8

10

2

0

12

6

16

4

14

8

10

Side View

Top of
Unit

30-1/2"

to floor

2

0

12

6

4

8

10

12" Mantel

7 3/4“ Mantel

3 1/2"
Mantel

Mantel Clearances

with Bay Option

13"

2

0

12

6

16

4

14

8

10

Drywall

Top of
Unit

7"

10"

Side View

6"
Standof

f

6"
Standof

f

Because of the extreme heat this fi replace emits, the mantel clearances are critical.
Combustible mantel clearances from top of unit are shown in Diagrams 1 & 2.

REGENCY

®

SERIES COMBUSTIBLE MANTEL CLEARANCES

These drawings are to scale at 1:6 (one inch = 6 inches)
Mantel can be installed anywhere in shaded area or higher using the above scale.

Note: Ensure the paint that is used on the mantel and the facing is "heat resistant" or the paint may discolour.

Note: A non-combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non-combustible

board.

Diagram 1

Diagram 2

INSTALLATION