Installation, Vertical termination - co-linear flex system – Regency Panorama P36E Medium Gas Fireplace User Manual

Page 29

Advertising
background image

P36E-4 Zero Clearance Direct Vent Gas Fireplace

29

VERTICAL TERMINATION - CO-LINEAR FLEX SYSTEM

THE APPLIANCE MUST NOT BE

CONNECTED TO A CHIMNEY FLUE

SERVING A SEPARATE SOLID FUEL

BURNING APPLIANCE.

This appliance is designed to be attached to
two 3" (76mm) co-linear aluminium fl ex run-
ning the full length of the chimney. See the
"Venting Arrangements" section for minimum
and maximum heights.

Masonry chimneys may take various contours which the fl exible liner will accommodate. However,
keep the fl exible liner as straight as possible, avoid unnecessary bending.

The Air Intake pipe must be attached to the inlet air collar of the termination cap.

Required Parts:

Part #

Description

946-529

Co-linear DV Vertical Termination Cap

948-305

3" Flex - 35 ft.

946-563

Co-Axial to Co-Linear Adapter Kit

which contains the following:

Co-linear Flex Adapter

Outer

Pipe

Inner

Pipe

Adapter

510-994 Flue

Adaptor

FPI Cabinet and/or Flat Wall Mantles may
be used in these applications ensuring
that clearances to combustibles are
maintained.

INSTALLATION

Advertising