MESSAGE FORMATTING

4.11 CONFIGURATION COPYING COMMANDS

4.11.1 Copy WLS8600 Series

Procedure:

Connect the master (correctly configured reader) and the slave (reader to be

configured) together through two RS-232 serial interface cables and external

power supply.
RS-232 Cables: CAB471 & CAB472
Power Supply: PG5

Using the slave reader, read the Restore Default barcode and then the RS-232

interface barcode from chapter 3 of this manual or from the Quick Reference

Guide.

With the master reader, read the Configuration Copy barcode below.

Copy Configuration

Ì$+ZZ0$-*Î

The configuration will be copied from the master to the slave reader. The slave

reader signals the end of the procedure with a series of beeps.

NOTE: The master reader can be configured for any interface.