5.2 STATUS INDICATORS

The scanner has two indicator LEDs and a Beeper. They signal several operating

conditions, which are described in the tables below.

H = high tone

L = low tone

WLS8600 READER START-UP

Beeper

¹

Meaning

L L L L

Parameters loaded correctly

H H H H
long tones

Parameter loading error, reading or writing error in the non volatile

memory

H L H L

Hardware error in EEPROM

WLS8600 READER CONFIGURATION

Beeper

¹

Meaning

H H H H

Correct entry or exit from Configuration mode

L

Good read of a command

L L L

Command read error


WLS8600 READER DATA ENTRY

Beeper

¹

LED

Good Read Spot Meaning

one beep

²

ON

ON

Correct read of a code in normal mode

H long

ON

ON

Successful advanced format

concatenation

H H H

Timeout expired – operation not

completed

H H long

Error in advanced data formatting

OFF

OFF

Ready to read a code

¹ Only the Beeper Intensity command can modify these signals.

² The data entry good read tone is user-configurable with all the Beeper commands

in the Reading Parameters section.