CODE SELECTION (continued)

DESCRIPTION

STRING

UPC A check digit transmission

disable

AAI0

enable

AAI1

UPC E check digit transmission

disable

AAJ0

enable

AAJ1

conversions

UPC E to UPC A

AAA

UPC E to EAN 13

AAB

UPC A to EAN 13

AAC

EAN 8 to EAN 13

AAD

ISBN Conversion codes

enable ISBN

AP1

enable ISSN

AP2

enable ISBN and ISSN

AP3

disable ISBN and ISSN

AP0

Code 39

disable Code 39 family

AB0

Standard

no check digit control

AB11

check digit control and transmission

AB12

check digit control without transmission

AB13

Full ASCII

no check digit control

AB21

check digit control and transmission

AB22

check digit control without transmission

AB23

CIP 39

AB3

Code 32

AB4

code length

AB*xxxx

2/5

disable Code 2/5 family

AC0

Interleaved 2/5

no check digit control

AC11xxxx

check digit control and transmission

AC12xxxx

check digit control without transmission

AC13xxxx

Normal 2/5 5 bars

no check digit control

AC21xxxx

check digit control and transmission

AC22xxxx

check digit control without transmission

AC23xxxx

Industrial 2/5 (IATA) no check digit control

AC31xxxx

check digit control and transmission

AC32xxxx

check digit control without transmission

AC33xxxx

Matrix 2/5 3 bars

no check digit control

AC41xxxx

check digit control and transmission

AC42xxxx

check digit control without transmission

AC43xxxx

CIP/HR

AC5

xxxx = ASCII numbers that define the code length where:
• First 2 digits = minimum acceptable code length.

• Second 2 digits = maximum acceptable code length.
The minimum code length must always be less than or equal to the maximum.
The maximum code length for all codes is 99 characters:
Examples:

0132 = variable length from 1 to 32 digits in the code.
1010 = 10 digit code length only.

128