Flash Updates
C-3
2. If the Flash can be completed safely, type Y. The letter “C”
repeatedly appears. It is the Xmodem prompt and continues to
appear until you send a binary file.
Important: Press Ctrl + X to cancel a Flash update procedure.
3. Select Transfer > Send File to display the send file dialog box.
4. Click Browse and navigate to the Flash file.
5. Double-click the file. Its name appears in the Filename box.
6. In the Protocol box, select Xmodem.
Figure 4.6 Example Send File Dialog Box
7. Click Send. A dialog box appears and reports the progress of the
download. When it is complete, the message “Operation Complete”
appears.
Important: Keep the device powered for 15 seconds after the operation
has completed.
8. Press the Enter key to return to the main menu.