Wiring the pd1 ground terminal, Wiring the pd1 ground terminal -6, Figure 3.5 pd1 module grounding – Rockwell Automation 160PD1 160 Profibus Communication Module User Manual

Page 16

Advertising
background image

3–6

Installation and Wiring

Wiring the PD1 Ground
Terminal

In addition to the ground connections shown in Appendix C of the
160 SSC manual, the ground terminal at the bottom of the PD1
module must be solidly connected (and as short as possible) to the
output ground terminal at TB2 of the 160 SSC drive, as shown in
Figure 3.4:

This connection shall have a cross section of 1.5 mm

2

.

Figure 3.5
PD1 Module Grounding

R/L1

S/L2

T/L3

PE

AC

nput Line

Shielded Enclosure

Enclosure Ground Connection

U/T1

Shielded Motor Cable

to TB3

Control
Cabinet

to Motor

V/T2

W/T3

T (L3)

S (L2)

R (L1)

= EMC Tested Shielded Cable Clamp (or Metal Conduit)

When the control circuitry is located outside of the 160 enclosure.

Control Wiring TB3

Motor Wiring TB2

Ground Terminal – PE

Line Power TB1

Line

Filter

DC+

W/T3

1

3 4 5 6 7 8 9 10 11

2

V/T2

U/T1

DC–

BR+

T/L3

S/L2

R/L1

BR–

FAULT

READY

Ground Terminal – PE

PD1 Communication
Module

PD1 Ground Terminal