Chapter

4

Modes of Operation

Chapter 4 contains the following information:

Powering up the drive with the PD1 Module installed

LED Indicators

Operation Modes

Powering Up the Drive

After you have installed the PD1 Module, apply power to the drive
and to the connected device. The READY LED should illuminate.
If it does not, refer to Chapter 8, Troubleshooting.

LED Indicators

The PD1 Module has three LEDs (see figure below) which provide
module status.

The LEDs are defined as follows:

COMM – The COMM LED has four possible states:

Green (steady)

Communication ok, data is exchanged.

Red (steady)

Diagnostics failed at power-up
or fatal error.

Red (flashing)

Profibus configuration fault (5 to 6 flashes).

Off

No communication takes place / No power

For more details refer to Troubleshooting, Table 8.A

FAULT – This LED tracks the fault status of the 160 Drive.
When no faults are present, the LED will be off. The LED will
illuminate (red) if a drive or an option board fault occurs.

READY – The Ready LED will illuminate (green) whenever the
module is connected to the drive and power is applied.

READY LED

COMM LED

FAULT LED