Drive state transitions, Drive state transitions -4 – Rockwell Automation 160IB1 InterBus Communication Module User Manual

Page 24

Advertising
background image

5–4

InterBus Parameter Descriptions and Data Protocol

Drive State Transitions

The following Figure 5.1 shows the most important state transitions

Figure 5.1
State Diagram

State Transition Description

1

Disable voltage
xxxx xx0x
Fast stop
xxxx x01x

10

SWITCH ON DISABLED

2

xxxx x110

Disable voltage
xxxx xx0x

Disable voltage
xxxx xx0x
Fast stop
xxxx x01x

7

READY TO SWITCH ON

3

Switch on
xxxx x111

6

SWITCHED ON

4

Shutdown
xxxx 011x

5

OPERATION ENABLED
(RUN commanded)

Fast stop
xxxx x01x

FAST STOP ACTIVE

11

DRIVE FAULT

Shutdown
xxxx x110

8

9

Shutdown
xxxx x110

Enable operation
xxxx 1111

15

12

Reset fault
0xxx xxxx
to
1xxx xxxx

Disable voltage
xxxx xx0x

State Transition Names and Numbers with associated Control Words (Low Byte) appear outside the boxes
Drive State Names with associated Status Words (Low Byte) appear inside the boxes

0011'0001

0011' 0111

0011' 0011

01x0'0000

00x1'1000

0001' 0111

(Power-up and diagnostics o.k.)

(No interlock)

(Drive enable interlock)

(Decelerate to 0 frequ.)

Transition Name

Triggered State
Transition

Control Word
Bit 7..... Bit 0

Description

Disable voltage
(High priority stop)

7, 9, 10, 12

xxxx xx0x

Stop operation (current loop off) from any STATE and after FAST STOP ACTIVE.

Shutdown
(Stop command)

2, 5, 6, 8

xxxx x110

Command to get to READY TO SWITCH ON after SWITCH ON DISABLED or fault
reset. Command to stop the drive if it is running.

Switch on *

3

xxxx x111

Command to get (from READY TO SWITCH ON) to SWITCHED ON state can be
replaced by Enable operation for running

Fast stop

7, 10, 11

xxxx x01x

Stop as fast as possible (with current )

Power-up successfull *

1

Needs no command as it is done inside the module itself

Enable operation

4

xxxx 1111

Start the drive if previous states are SWITCHED ON or READY TO SWITCH ON.

Reset fault

15

0xxx xxxx to
1xxx xxxx

Comand to clear a present fault

* These transitions are not needed for operation.

Note: The state SWITCHED ON is like power on to the drive, but this is a virtual state because the power to

the drive is applied all the time in our case.