Appendix

A

Specifications

Electrical

Supply Voltage

Supplied by Drive

Power Consumption

1.4 Watts (280 mA) maximum

Environmental

Ambient Temperature

Operating

0 to 65

°

C (32 to 149

°

F)

Storage

–40 to 85

°

C (–40 to 185

°

F)

Relative Humidity

0 to 95% non-condensing

Vibration

1.0 G Operational
2.0 G Non-operational

Shock

15.0 G Operational
30.0 G Non-operational

Altitude

1,000 m (3,300 ft.) without derating

Communications

Baud Rate

500 kBaud

Protocol

Drivecom 20 (21)

Mechanical

Dimensions are in Millimeters and (inches)

(1)

Required for module removal.

(2)

Module adds this dimension to the overall drive depth.

(3)

Required for connecting cable

(2)
21.4
(0.85)

(1)
17.34
(0.68)

(3)
60
(15)