Sample Ladder Listing

Publication 1403-5.1

Rung 2:8
Perform appropriate block transfer read.
| +EQU–––––––––––––––+ +JSR–––––––––––––––+ |
|–+EQUAL +––––––––––––––––––––––––––––––––––––+JUMP TO SUBROUTINE+–|
| |Source A N9:0| |SBR file number 3| |
| | 40| +––––––––––––––––––+ |
| |Source B 41| |
| | | |
| +––––––––––––––––––+ |
Rung 2:9
Perform appropriate block transfer read.
| +EQU–––––––––––––––+ +JSR–––––––––––––––+ |
|–+EQUAL +––––––––––––––––––––––––––––––––––––+JUMP TO SUBROUTINE+–|
| |Source A N9:0| |SBR file number 3| |
| | 40| +––––––––––––––––––+ |
| |Source B 42| |
| | | |
| +––––––––––––––––––+ |
Rung 2:10
Perform appropriate block transfer read.
| +EQU–––––––––––––––+ +JSR–––––––––––––––+ |
|–+EQUAL +––––––––––––––––––––––––––––––––––––+JUMP TO SUBROUTINE+–|
| |Source A N9:0| |SBR file number 3| |
| | 40| +––––––––––––––––––+ |
| |Source B 43| |
| | | |
| +––––––––––––––––––+ |
Rung 2:11
Perform appropriate block transfer read.
| +EQU–––––––––––––––+ +JSR–––––––––––––––+ |
|–+EQUAL +––––––––––––––––––––––––––––––––––––+JUMP TO SUBROUTINE+–|
| |Source A N9:0| |SBR file number 3| |
| | 40| +––––––––––––––––––+ |
| |Source B 44| |
| | | |
| +––––––––––––––––––+ |
Rung 2:12
Perform appropriate block transfer read.
| +EQU–––––––––––––––+ +JSR–––––––––––––––+ |
|–+EQUAL +––––––––––––––––––––––––––––––––––––+JUMP TO SUBROUTINE+–|
| |Source A N9:0| |SBR file number 3| |
| | 40| +––––––––––––––––––+ |
| |Source B 45| |
| | | |
| +––––––––––––––––––+ |
Rung 2:13
Perform appropriate block transfer read.
| +EQU–––––––––––––––+ +JSR–––––––––––––––+ |
|–+EQUAL +––––––––––––––––––––––––––––––––––––+JUMP TO SUBROUTINE+–|
| |Source A N9:0| |SBR file number 3| |
| | 40| +––––––––––––––––––+ |
| |Source B 46| |
| | | |
| +––––––––––––––––––+ |
Rung 2:14
Perform appropriate block transfer read.
| +EQU–––––––––––––––+ +JSR–––––––––––––––+ |
|–+EQUAL +––––––––––––––––––––––––––––––––––––+JUMP TO SUBROUTINE+–|
| |Source A N9:0| |SBR file number 3| |
| | 40| +––––––––––––––––––+ |
| |Source B 47| |
| | | |
| +––––––––––––––––––+ |
Rung 2:15
Perform appropriate block transfer read.
| +EQU–––––––––––––––+ +JSR–––––––––––––––+ |
|–+EQUAL +––––––––––––––––––––––––––––––––––––+JUMP TO SUBROUTINE+–|
| |Source A N9:0| |SBR file number 3| |
| | 40| +––––––––––––––––––+ |
| |Source B 48| |
| | | |
| +––––––––––––––––––+ |
Rung 2:16
Perform appropriate block transfer read.
| +EQU–––––––––––––––+ +JSR–––––––––––––––+ |
|–+EQUAL +––––––––––––––––––––––––––––––––––––+JUMP TO SUBROUTINE+–|
| |Source A N9:0| |SBR file number 3| |
| | 40| +––––––––––––––––––+ |
| |Source B 49| |
| | | |
| +––––––––––––––––––+ |

Rung 2:8

Real time power BTR.

Rung 2:9

Cumulative power BTR.

Rung 2:10

Device configuration BTR.

Rung 2:11

Communication configuration
BTR.

Rung 2:12

Demand BTR.

Rung 2:13

Even harmonic distortion BTR.

Rung 2:14

Odd harmonic distortion BTR.

Rung 2:15

Even harmonic magnitude
BTR.

Rung 2:16

Odd harmonic magnitude BTR.

Advertising