Rockwell Automation 1403-NSC Smart Communication Card Instruction Sheet User Manual

Page 78

Advertising
background image

D–28

Sample Ladder Listing

Publication 1403-5.1

Rung 2:14
| Odd |
| Harmonic |
| Distortion |
| +EQU–––––––––––––––+ N47:0 +MSG––––––––––––––––––––+ |
|–+EQUAL +––]/[–––––––––––––––––––––+READ/WRITE MESSAGE +–(EN)–|
| |Source A N9:0| 15 |Type PEER–TO–PEER+–(DN) |
| | 40| |Read/Write READ+–(ER) |
| |Source B 47| |Target Device 500CPU| |
| | | |Local/Remote LOCAL| |
| +––––––––––––––––––+ |Control Block N47:0| |
| |Control Block Length 14| |
| +–––––––––––––––––––––––+ |
Rung 2:15
| Even |
| Harmonic |
| Magnitude |
| +EQU–––––––––––––––+ N48:0 +MSG––––––––––––––––––––+ |
|–+EQUAL +––]/[–––––––––––––––––––––+READ/WRITE MESSAGE +–(EN)–|
| |Source A N9:0| 15 |Type PEER–TO–PEER+–(DN) |
| | 40| |Read/Write READ+–(ER) |
| |Source B 48| |Target Device 500CPU| |
| | | |Local/Remote LOCAL| |
| +––––––––––––––––––+ |Control Block N48:0| |
| |Control Block Length 14| |
| +–––––––––––––––––––––––+ |
Rung 2:16
| Odd |
| Harmonic |
| Magnitude |
| +EQU–––––––––––––––+ N49:0 +MSG––––––––––––––––––––+ |
|–+EQUAL +––]/[–––––––––––––––––––––+READ/WRITE MESSAGE +–(EN)–|
| |Source A N9:0| 15 |Type PEER–TO–PEER+–(DN) |
| | 40| |Read/Write READ+–(ER) |
| |Source B 49| |Target Device 500CPU| |
| | | |Local/Remote LOCAL| |
| +––––––––––––––––––+ |Control Block N49:0| |
| |Control Block Length 14| |
| +–––––––––––––––––––––––+ |
Rung 2:17
| Even |
| Harmonic |
| Phase |
| +EQU–––––––––––––––+ N50:0 +MSG––––––––––––––––––––+ |
|–+EQUAL +––]/[–––––––––––––––––––––+READ/WRITE MESSAGE +–(EN)–|
| |Source A N9:0| 15 |Type PEER–TO–PEER+–(DN) |
| | 40| |Read/Write READ+–(ER) |
| |Source B 50| |Target Device 500CPU| |
| | | |Local/Remote LOCAL| |
| +––––––––––––––––––+ |Control Block N50:0| |
| |Control Block Length 14| |
| +–––––––––––––––––––––––+ |
Rung 2:18
| Odd |
| Harmonic |
| Phase |
| +EQU–––––––––––––––+ N51:0 +MSG––––––––––––––––––––+ |
|–+EQUAL +––]/[–––––––––––––––––––––+READ/WRITE MESSAGE +–(EN)–|
| |Source A N9:0| 15 |Type PEER–TO–PEER+–(DN) |
| | 40| |Read/Write READ+–(ER) |
| |Source B 51| |Target Device 500CPU| |
| | | |Local/Remote LOCAL| |
| +––––––––––––––––––+ |Control Block N51:0| |
| |Control Block Length 14| |
| +–––––––––––––––––––––––+ |
Rung 2:19
| Diagnostic |
| +EQU–––––––––––––––+ N52:0 +MSG––––––––––––––––––––+ |
|–+EQUAL +––]/[–––––––––––––––––––––+READ/WRITE MESSAGE +–(EN)–|
| |Source A N9:0| 15 |Type PEER–TO–PEER+–(DN) |
| | 40| |Read/Write READ+–(ER) |
| |Source B 52| |Target Device 500CPU| |
| | | |Local/Remote LOCAL| |
| +––––––––––––––––––+ |Control Block N52:0| |
| |Control Block Length 14| |
| +–––––––––––––––––––––––+ |

Rung 2:17

Even harmonic phase BTR.

Rung 2:14

Odd harmonic distortion BTR.

Rung 2:15

Even harmonic magnitude
BTR.

Rung 2:16

Odd harmonic magnitude BTR.

Rung 2:19

Diagnostic BTR.

Rung 2:18

Odd harmonic phase BTR.

Advertising