Chapter 3, Introduction, Prepower drive checks – Rockwell Automation 1395 Reel Tension Paster Adapter User Manual

Page 21: Power terminations within the drive are tight, All control wiring is secure, All wiring and cabinets are properly grounded, All control boards are secure, All terminal blocks are secure, Terminology, Parameter

Advertising
background image

Publication 1395-RTP-5.1 - September 1997

Chapter

3

Start-Up Instructions

Introduction

The following start-up instructions should be used to fine tune the
operation of the RTP Drive. The complete start-up procedure for the
associated Drive can be found in the Bulletin 1395 Installation and
Maintenance Manual. Read and understand the complete procedure
prior to attempting start-up of the RTP Drive.

Important: Before attempting to operate the Drive, ensure that the

mechanics of the associated press system have been
checked and properly set up. Check the:

gearbox fluid level

type of lubricant used

belt tension

associated wiring

mag pick-up gap per Goss specifications

Pre-Power Drive Checks –

1. Power Terminations within the Drive are tight

2. All control wiring is secure

3. All wiring and cabinets are properly grounded

4. All control boards are secure

5. All terminal blocks are secure

Terminology

Parameter

Memory location used to store Drive set-up data, or to monitor real
time input or output information. Each parameter is assigned a name
and number which does not change.

Set-Up Parameter

Parameter whose values do not change during normal operation of the
Drive. The Set-Up Parameters are used for scaling and calibration of
specific Drive functions which are application and/or hardware
dependent.

Read-Only Parameter

Parameter whose value cannot be changed by any external device.
Special Parameter used only for the purpose of monitoring several
internal strategic variables.

Advertising