Table 2: Parameter List, Factory (Initial) Settings

Parameter

Value

Description

*

551

0.0

ANALOG OFFSET #1

553

0.0

DIGITAL OFFSET #1

*

558

1500

DANCER FULL POSITION

*

559

750

DANCER MID-POSITON

*

561

131

PRESS REF PPR

*

562

2566

MAX PRESS REF RPM

563

400

VELOCITY KI LOW

564

1700

VELOCITY KI HIGH

565

150

VELOCITY KP LOW

566

425

VELOCITY KP HIGH

567

50

PROCESS REG KI

*

569

30

VP KI/KP SWITCH RPM

*

570

-20

LOW SUM RRDH

571

0

LOW SUM NORMAL

600

625

VEL INDIRECT 1 (P.163)

601

721

VEL INDIRECT 2 (P.164)

602

659

VEL INDIRECT 3 (P.165)

603

660

VEL INDIRECT 4 (P.166)

606

1750

BASE MOTOR SPEED

*

607

-20

REVERSE SPEED LIMIT

*

608

1560

FORWARD SPEED LIMIT BELT
MOTOR RPM PER CHART

609

210

ENCODER PPR

610

500

RATED MOTOR VOLTAGE

611

20.6

MOTOR ARMATURE FLA

612

1.2

RATED FIELD MOTOR CURRENT

613

6

MOTOR INERTIA

614

5.78

ARMATURE RESISTANCE

615

40

RATED ARMATURE BRIDGE
CURRENT

616

2.1

RATED FIELD BRIDGE CURRENT

617

460

RATED AC LINE VOLTAGE

621

0

FEEDBACK DEVICE TYPE

628

1

PROCESS TRIM SELECT

*

633

20

PRESET SPEED 1

*

634

-20

PRESET SPEED 2

635

0

PRESET SPEED 3