Rockwell Automation 1395 Reel Tension Paster Adapter User Manual

Page 26

Advertising
background image

Publication 1395-RTP-5.1 - September 1997

3-6

Start-Up Instructions

* DEFAULTS may be adjusted per installation as required.

651

20

ACCEL TIME

652

10

DECEL TIME

659

400

KI VELOCITY LOOP

660

150

KP VELOCITY LOOP

661

65535

KF VELOCITY LOOP

663

150

FORWARD BRIDGE CURRENT
LIMIT

664

150

REVERSE BRIDGE CURRENT LIMIT

713

0

PROCESS TRIM FILTER

714

0

INTEGRAL PRELOAD

715

0

KI INTEGRAL GAIN

716

4096

KP PROPORTIONAL GAIN

717

-165

PROCESS TRIM LOW LIMIT

718

165

PROCESS TRIM HIGH LIMIT

719

-1

P/I REGULATOR OUTPUT GAIN

720

150

OVERLOAD PENDING LEVEL

721

0

PROCESS TRIM LOW SUM

722

1750

PROCESS TRIM HIGH SUM

724

75

ABSOLUTE OVERSPEED

725

10

EXTERNAL OVERTEMP DELAY

726

10

SCR OVERTEMP DELAY

727

2

STALL DELAY

728

1

AC LINE TOLERANCE DELAY

730

1

FIELD FAILURE DELAY

731

15

TACH LOSS CEMF

732

0.5

TACH LOSS VELOCITY

733

1

ARM BRIDGE TYPE

734

155

K DISCONTINOUS

735

1659

KP ARMATURE LOOP

736

136

KI ARMATURE LOOP

737

16384

KP FIELD LOOP

738

512

KI FIELD LOOP

*

739

12350

K ARM VOLTS

*

740

7200

K AC VOLTS

Table 2: Parameter List, Factory (Initial) Settings (Continued)

Parameter

Value

Description

Advertising