Rockwell Automation 1786-RPFRXL ControlNet Fiber Ring Modules Installation Instructions User Manual

Page 35

Advertising
background image

ControlNet Fiber-optic Ring Repeater Modules 35

Rockwell Automation Publication 1786-IN003D-EN-P - April 2011

Radiated RF immunity

IEC 61000-4-3

10V/m with 1 kHz sine-wave 80% AM from
80…2000 MHz
10V/m with 200 Hz 50% Pulse 100% AM at
900 and 1890 MHz
1V/m with 1 kHz sine-wave 80% AM from
2000…2700 MHz

EFT/B immunity

IEC 61000-4-4

±4 kV at 5 kHz on signal ports

Surge transient immunity

IEC 61000-4-5

±1 kV line-line (DM) and ±2 kV line-earth
(CM) on signal ports

Conducted RF Immunity

IEC 61000-4-6

10V rms with 1 kHz sine-wave 80% AM
from 150 kHz…80 MHz

Environmental Specifications - 1786-RPFRL/B, 1786-RPFRXL/B

Attribute

1786-RPFRL/B, 1786-RPFRXL/B

Advertising
This manual is related to the following products: