3. Installation Guidelines

Suggestion

Lamp runtime is

105 hours

It is advisable to

adjust the Z-axis

of the lamp to
obtain maximum

light output

(see owners manual)

<ENTER> to confirm

Menu 3-1

The user can now adjust the Z-axis by following the next procedure.

How to readjust.

1. On the side of the inputs, turn the retaining bolt a quarter counter clockwise.

2. Flip the cover to the left side and take off. (image 3-15)

3. Start up the adjustment mode and select Service. (menu 3-2)

4. Select Lamp. The Z-axis indication (lamp menu in service mode) will be helpful while turning screw B . (menu 3-3)

5. Loosen the nut A (image 3-16)on the back of the lamp casing (nutdriver 10).

6. Adjust the screw B (image 3-16)with an Allen key by turning a little clockwise until the maximum light output is reached (the

maximum value of the Z-AXIS indication on the lamp menu).

7. Fasten the nut on the back of the lamp casing to secure this position (nutdriver 10).

ADJUSTMENT MODE

Select a path from below :

RANDOM ACCESS

INSTALLATION

SERVICE

Select with

or

then <ENTER>

<EXIT> to return

Menu 3-2

SERVICE

IDENTIFICATION

CHANGE PASSWORD
CHANGE LANGUAGE

CHANGE PROJ. ADDRESS
SERIAL COMMUNICATION

NETWORK

LAMP

DIMMING
MORE...

Select with

or

then <ENTER>

<EXIT> to return

Menu 3-3

LAMP

Constant Light output [OFF]

Using [RS port]

Mode [NORMAL]

Serial number :

R101111

Article number :

R9840xxx

Run time :

10 hours

Remaining run time :

490

hours

Number of strikes :

10

Z_AXIS : 100

Select with

or

then <ENTER>

<EXIT> to return.

Menu 3-4

Image 3-15
Lamp adjustment access

R5976563 BARCOR10 SLM 20/10/2004

17