125

Event (cont.) Loss of Signal

Loss of Frame
Set Code Received
Reset Code Received
UA1 Received
CV Threshold Exceeded
FE Threshold Exceeded
CRC Threshold Exceeded
External ALarm Asserted
Power Outage
UAS Outage
Flash N.V. Log Error
Clear User 4 Day Archive
Clear User 14 Day Totals

Module

When All is selected, all of the preceding status changes will be logged as
events.

When Network is selected, the following status changes will be logged as
events:
Network
Loss of Signal
Loss of Frame
Set Code Received
Reset Code Received
BPV Threshold Exceeded
CRC Threshold Exceeded
OOF Threshold Exceeded

When AUX is selected, the following status changes will be logged as
events:
Loss of Signal
Loss of Frame

Module

When System is selected, the following status changes will be logged as
events.
External Alarm
Power Supply Failure

Event

This field allows a particular type of event to be displayed
Enter an event index or use the Up/Down keys to scroll through the event
options. While selecting the event, the event description text changes with
the index. The event description text is displayed under the Description
column in the Event Log menu.
If the Event field is left blank, the Event filter parameter is disabled.

0, All

Seq. No.

This value uniquely identifies an event in a certain unit. This field is read
only.

Status

Identifies the condition of the event described in the description field. This
field is read-only.

Module

Identifies the module type. This field is read-only.

Description

Identifies the status change/event. This field is read-only.

Parameter

Description