A-2

SA500 Power Modules

Maximum Power Dissipation

Power Module DC-to-DC Converter

Internally powered via DC Bus Supply

DC Output to PMI Regulator

5 VDC (+/- 5%)

24 VDC (+/- 15%)

+/- 15 VDC (+/- 5%)

System Power Requirements

+5 VDC @ 1500 mA (3000 mA maximum)

+15 VDC @ 300 mA

- 15 VDC @ 300 mA

Fiber-Optic Port

Transmitter: 1

Receiver: 1

Data rate: 10 Mbd

Coding: Manchester

Protocol: HDLC (compatible with UDC module)

Maximum distance to UDC: 750 m (2500 ft)

Rail I/O

Channels: 2

Analog/digital rails only; no local heads

Resolver Input Specifications

Resolution: 12 or 14 bits (software-selectable)

Required resolver accuracy (electrical)

12-bit configuration: 5 arc minutes (typical)

14-bit configuration: 1 arc minute

615055-1R

14 A

120 W

615055-1S

28 A

180 W

615055-1T

35 A

275 W

615055-1V

48 A

300 W