Sensor) – Bendix Commercial Vehicle Systems EC-60 ESP CONTROLLERS ADV User Manual

Page 38

Advertising
background image

38

1st . Blink

Code

21

Location:

Steering Angle Sensor

Troubleshooting Diagnostic Trouble Codes:

Steering Angle Sensor (SAS-60

sensor)

2nd .

Blink

Code

Diagnostic Trouble

Code Description

Repair Information

1

SAS Not Calibrated

SAS has not been calibrated. Perform SAS calibration procedure.

2

SAS Calibration in

Progress

SAS calibration procedure is underway.

3

SAS Static Signal

SAS signal incorrect. Verify proper installation of the SAS. Verify proper wiring

between the ECU and the SAS. Check SAS output.

4

SAS Signal Out of

Range

SAS signal incorrect. Verify proper installation of the SAS. Verify proper wiring

between the ECU and the SAS. Check SAS output. Perform SAS calibration

procedure.

5

SAS Signal Reversed

SAS signal is reversed. Verify proper installation of the SAS. Verify proper wiring

between the ECU and the SAS. Check SAS output.

6

SAS Invalid Signal

SAS signal is invalid. Verify proper installation of the SAS. Verify proper wiring

between the ECU and the SAS. Check SAS output. Verify that correct SAS is being

used.

7

SAS Gradient Error

SAS signal is invalid. Verify proper installation of the SAS. Verify proper wiring

between the ECU and the SAS. Check SAS output. Verify that correct SAS is being

used.

8

SAS CAN Timeout

Loss of CAN communications between the ECU and the SAS. Verify proper wiring

between the ECU and the SAS. Check SAS output.

9

SAS Long Term

Calibration Error

SAS calibration error. Verify proper installation of the SAS. Verify proper wiring

between the ECU and the SAS. Check SAS output. Verify that correct SAS is being

used. Verify proper ECU programming. Perform SAS calibration procedure.

10

SAS Plausibility Check

ECU has detected incorrect SAS signal as compared to the Yaw Rate sensor signal.

Verify proper installation of the SAS. Verify proper wiring between the ECU and the

SAS. Check SAS output. Verify that correct SAS is being used. Verify proper ECU

programming. Perform SAS calibration procedure.

Advertising