Bendix Commercial Vehicle Systems EC-60 ESP CONTROLLERS ADV User Manual

Page 58

Advertising
background image

58

APPENDIx C: UDS Codes and their Bendix Blink Code Equivalents

UDS

Code

US-

Spec .

Blink

Code

J1587

PID194

(SID/

FMI)

J1939/73

DM1/2

SPN/FMI

DTC Description

Lamp

Status

ABS

ATC/

ESP

91

21-07

089-02

1807-02

SAS Gradient Error

-

ON

92

21-09

089-02

1807-02

SAS Long Term Calibration Error

-

ON

93

07-08

007-13

0795-13

SA Left PMV Configuration Error

ON

ON

94

21-03

089-02

1807-02

SAS Static Signal

-

ON

95

21-05

089-02

1807-02

SAS Signal Reversed

-

ON

96

21-10

089-02

1807-02

SAS Plausibility Check (Ref Yaw Rate)

-

ON

97

05-03

004-02

0792-02

DA Right WSS Open or Shorted

ON

ON

98

22-05

103-09

1808-09

YRS CAN Timeout

-

ON

99

22-01

103-02

1808-02

YRS Signal Out of Range

-

ON

100 22-03

103-02

1808-02

YRS Invalid Signal

-

ON

101 05-05

004-07

0792-07

DA Right WSS Wheel End

ON

ON

102 22-06

103-02

1808-02

YRS Static BITE Error

-

ON

103 05-01

004-01

0792-01

DA Right WSS Excessive Air Gap

ON

ON

104 05-02

004-14

0792-14

DA Right WSS Output Low @ Drive-Off

ON

ON

105 05-06

004-08

0792-08

DA Right WSS Erratic Sensor Signal

ON

ON

106 05-04

004-10

0792-10

DA Right WSS Loss of Sensor Signal

ON

ON

109 22-07

103-02

1808-02

YRS Dynamic BITE Error

-

ON

110 22-04

103-02

1808-02

YRS Gradient Error

-

ON

111

22-08

103-02

1808-02

YRS Fast Calibration Error

-

ON

112 22-09

103-02

1808-02

YRS Static Calibration Error

-

ON

113 10-06

045-05

0798-05

DA Right PMV HLD Solenoid Open Circuit

ON

ON

114 10-04

045-04

0798-04

DA Right PMV HLD Solenoid Shorted to Ground

ON

ON

115 10-05

045-03

0798-03

DA Right PMV HLD Solenoid Shorted to Voltage

ON

ON

116 10-07

010-05

0798-05

DA Right PMV CMN Open Circuit

ON

ON

117 10-03

051-05

0798-05

DA Right PMV REL Solenoid Open Circuit

ON

ON

118 10-01

051-04

0798-04

DA Right PMV REL Solenoid Shorted to Ground

ON

ON

119 10-02

051-03

0798-03

DA Right PMV REL Solenoid Shorted to Voltage

ON

ON

120 22-10

103-02

1808-02

YRS Normal Calibration Error

-

ON

121 22-11

103-02

1808-02

YRS Sensitivity Calibration Error

-

ON

122 22-12

103-02

1808-02

YRS Plausibility Check (Ref Yaw Rate)

-

ON

123 22-02

103-02

1808-02

YRS Sensor Reversed Signal

-

ON

124 22-13

103-02

1808-02

YRS Plausibility Error (Inside Model Based Limits)

-

ON

125 10-08

010-13

0798-13

DA Right PMV Configuration Error

ON

ON

126 22-14

103-02

1808-02

YRS Plausibility Error (Outside Model Based Limits)

-

ON

127 11-06

231-02

0639-02

J1939 ESP Messages Invalid Data

-

ON

128 13-13

254-12

0629-12

ECU (80)

ON

ON

129 03-03

002-02

0790-02

SA Right WSS Open or Shorted

ON

ON

130 06-08

251-02

0627-02

Input Voltage Excessive Noise (Temp.)

ON

ON

131 06-09

251-14

0627-14

Input Voltage Excessive Noise (Latched)

ON

ON

132 12-22

103-02

1808-02

ESP Sensor Voltage Out of Range

-

ON

133 03-05

002-07

0790-07

SA Right WSS Wheel End

ON

ON

134 24-06

077-07

1067-07

PS Not Calibrated

-

ON

135 03-01

002-01

0790-01

SA Right WSS Excessive Air Gap

ON

ON