AIR DRYER TROUBLESHOOTING CHART

SYMPTOMS

CAUSE

REMEDY

2. Water and/or oil in

the supply or service

reservoir (continued).

E. (Continued)

Air Compressor Size - Although the Bendix

®

AD-IP

®

air dryer can be used in conjunction with

larger compressors, it was designed primarily for

units rated for up to 30 CFM. It is recommended

that when using the AD-IP air dryer with a

compressor which has a rated displacement

exceeding 30 CFM that an authorized Bendix

®

parts outlet or Bendix marketing representative

be contacted for assistance.

F. Air compressor discharge

and/or air dryer inlet

temperature too high.

F. Restricted discharge line. See Appendix A, Table

A, column 1 & 2 for recommended sizes. If the

discharge line is restricted or more than 1/16”

carbon build-up is found, replace the discharge line.

Replace as necessary.
Discharge Line Freeze-Up. The discharge line

must maintain a constant slope down from the

compressor to the air dryer inlet fitting to avoid low

points where ice may form and block the flow. If,

instead, ice blockages occur at the air dryer inlet,

insulation may be added here, or if the inlet fitting is

a typical 90° fitting, it may be changed to a straight

or 45° fitting. For more information on how to help

prevent discharge line freeze-ups, see Bendix

Bulletins TCH-008-021 and TCH-008-022. Shorter

discharge line lengths or insulation may be required

in cold climates.
Insufficient coolant flow through compressor.

Inspect coolant line. Replace as necessary (Inside

Diameter (I.D.) is 1/2” min.). Inspect the coolant

lines for kinks and restrictions and fittings for

restrictions. Replace as necessary. Verify coolant

lines go from engine block to compressor and back

to the water pump. Repair as necessary.
Restricted air inlet (not enough air to compressor).

Check compressor air inlet line for restrictions,

brittleness, soft or sagging hose conditions etc.

Repair as necessary. Inlet line size is 3/4 ID.

Maximum restriction requirement for compressors

is 25 inches of water. Check the engine air filter and

service if necessary (if possible, check the air filter

usage indicator).
Poorly filtered inlet air (poor air quality to

compressor). Check for leaking, damaged or

malfunctioning compressor air inlet components

(e.g. induction line, fittings, gaskets, filter bodies,

etc.). Repair inlet components as needed.
Note: Dirt ingestion will damage the compressor

and is not covered under the warranty.
If you found excessive oil present in the service

reservoir and you did not find any issues above,

the compressor may be passing oil.
Replace the compressor. If still under warranty,

follow the normal warranty process.