24

BENDIX

®

AD-IP

®

AIR DRYER TROUBLESHOOTING CHART

SYMPTOMS

CAUSE

REMEDY

5. Constant exhaust

of air at air dryer

purge valve exhaust.

(Charge mode.)

A. Air dryer purge valve is

leaking excessively.

A. With the compressor loaded, apply a soap solution

on the purge valve exhaust, to test for excessive

leakage. Refer to Technical Bulletin TCH-008-040.

Repair the purge valve as necessary.

B. Compressor fails to unload

(stop compressing air) and

the air dryer purge exhaust

makes “sputtering” or

“popping” sound.

B. Confirm the failure to unload by increasing &

decreasing engine RPM and noting change in the

rate of leakage and intensity of accompanying

leakage sound. Repair/replace compressor

unloaders.

C. Purge control line connected

to reservoir or exhaust port

of governor.

C. Purge control line must be connected to unloader

port of governor.

D. Purge valve frozen open -

malfunctioning heater and

thermostat, wiring, blown

fuse.

D. Test the heater and thermostat as described in

Preventative Maintenance Section.

E. Excessive system leakage.

E. See Symptom #1.

F. Purge valve stays open -

supply air leaks to control

side.

F. Repair the purge valve and housing.

6. Can not build system

air pressure.

A. Inlet and outlet air

connections reversed.

A. Connect compressor discharge to the air dryer

supply port. Reconnect the lines properly.

B. Check valve between the air

dryer and first reservoir.

B. Test the check valve for proper operation. Repair

or replace as necessary.

C. Kinked or blocked (plugged)

discharge line.

C. Check to determine if air passes through the

discharge line. Check for kinks, bends, excessive

carbon deposits, or ice blockage.

D. Excessive bends in

discharge line (water collects

and freezes)

D. Discharge line should be constantly sloping from

the compressor to the air dryer with as few bends

as possible.

E. Refer to Symptom 4, Causes

E & F.

E. Refer to Symptom #4, Remedies E & F.

7. Air dryer does not

purge or exhaust air.

A. Missing, broken, kinked,

frozen, plugged or

disconnected purge control

line.

A. Inspect control line from the governor UNL

(unloader) port to control port of air dryer. Test to

determine if air flows through purge control line

when compressor unloaded. Check for undrilled

fittings. (See Symptom #4, Remedy C.)

B. Faulty air dryer purge valve. B. After determining the air reaches the purge valve

(Remedy A above), repair the purge valve.

C. See Causes, B, E, G for

Symptom #4.

C. Refer to Remedies B, E, G for Symptom #4.