Purge Valve Maintenance Kits

Purge Valve

Assembly Type

Configuration /

Installation

Piece

Number

Purge Valve Assembly

Kit for climate conditions

above -40°C (-40°F)

Bendix

®

AD-IP

®

Air Dryer

K022105

Bendix

®

AD-IP

®

EverFlow

®

Air Dryer

Module

AD-IP

Drop-In

Air Dryer

K031560

Arctic Purge Valve

Assembly Kit for climate

conditions between

-40°C to -50°C

(-40°F to -58°F)

AD-IP

Air Dryer

K031559

AD-IP

EverFlow

Air Dryer Module

AD-IP

Drop-In Air Dryer

K031561

Purge Valve Assembly

Kit for climate conditions

above -40°C (-40°F)

Bendix

®

AD-IP

®

Air Dryer

Discharge Line Unloader

K031562

Arctic Purge Valve

Assembly Kit for climate

conditions between -40°C

to -50°C (-40°F to -58°F)

AD-IP

Air Dryer Discharge

Line Unloader

K031563

Maintenance Kits

Description

Piece

Number

Cartridge Bolt Kit

109498

Desiccant Cartridge Service New

065624

Desiccant Cartridge Remanufactured

109493X

Bendix

®

PuraGuard

®

Coalescing Cartridge Kit -

Service New

065624PG

PuraGuard Coalescing Cartridge Kit -

Reman Exchange

109493PGX

Delivery Check Valve Kit

109494

Exhaust Cover Kit

5011327

Extended Purge Kit 3/8" U-Bolt; 90in

3

Reservoir

5012561N

Extended Purge Kit 3/8" U-Bolt; 288in

3

Reservoir

5008972N

Extended Purge Kit 1/2" U-Bolt; 90in

3

Reservoir

5005309N

12 Volt Heater & Thermostat Kit

109495

24 Volt Heater & Thermostat Kit

109496

Mounting Bracket Kit

5001247

Silencer Kit

K021189

Wiring Harness & Splicing Kit

109871N

2. Drain

all reservoirs to 0 psi. Compressor discharge

line may still contain residual pressure.

3. Identify and disconnect the three air lines from the end

cover and note the position of end cover ports relative

to the vehicle.

AD-IP

®

AIR

DRYER END

COVER

LOCKING LATCH

(MUST BE INSERTED UNTIL IT

SNAPS OVER THE MATING CONNECTOR

ON AD-IP

®

AIR DRYER

TOP VIEW

SIDE VIEW

FIGURE 7 -

BENDIX

®

AD-IP

®

AIR DRYER HEATER AND

THERMOSTAT CONNECTOR

A two lead wire harness with attached weather resistant

connector is available as a service part. One of the two

leads is connected to the engine “kill switch” or ignition while

the other must be connected to a good vehicle ground. A

fuse is installed in the lead carrying vehicle power; install

a 10 amp fuse for the 12 volt heater and a 5 amp fuse for

the 24 volt heater.

Use 14 AWG wire if it is necessary to lengthen the wire

harness leads. Make certain all splices are weatherproofed.

Tie wrap or support all electrical wires leading to the AD-IP

air dryer.

WEATHERPROOF

ACCORDIAN

SEAL

HEATER &

THERMOSTAT

CONNECTOR

4. Unplug the vehicle wiring harness from the heater

and thermostat assembly connector on the end cover

assembly.

5. Remove the four bolts that secure both the upper and

lower mounting brackets to the vehicle, and remove

the air dryer from the vehicle.