Complaint: System Pressure Goes to 150+ psi

• Drain the air system to zero (0) psi, remove/disconnect

the governor from the compressor. Start the engine

and note the air pressure rise on the dash gauges.

Apply 120 psi of shop air to compressor unloader port.

If the air pressure continues to rise, repair compressor

unloaders or replace compressor. If air ceases to rise,

repair or replace governor.

COMPLAINTS COMMON TO THE CHARGING & AIR SUPPLY SYSTEM

Complaint: Low Pressure Warning After Only 1

or 2 Applications

• Brakes out of adjustment: adjust brakes.
• Excessive system leakage on the service (application)

side of system: Build the system pressure to 120 psi

and turn the engine off. With the park brakes released,

make a full service application and note the dash

gauges for two (2) minutes. A pressure drop on either

gauge should not exceed 4 psi. (two (2) psi per min.)

If the pressure drop is excessive, find the leakage in

service system, if OK, then proceed to next complaint.

• Incorrect low pressure switch in use or setting

incorrect: Build the system pressure to 120 psi, with

the engine OFF and the ignition ON, slowly drain the

air pressure from one service reservoir. Low pressure

warning on at minimum 60 psi, maximum 10–15 psi

less than governor cut-in pressure.