Attach a swivel between the grip and pull line. Pull by the messenger only! Start each pull very slow to remove

slack in the pull line and cable. Never start with a sudden jerk, as this will damage the cable at the blocks. While

pulling, monitor the cable for binding in the blocks/rollers, and rubbing against the poles. Use cable reel brakes

as necessary. During the placing

operation do not exceed the maximum

rated pulling tension of the steel. After the

cable has been placed, tension should

be applied to the strand only. Follow

clearance guidelines found in the current

NESC Rules 250-252. Use SpanMaster

®

to calculate/verify sag and tension.

Note: Prior to placing the strand in the clamps, the cable

and strand must be separated using the MWS-xxx tool.

Cable and Strand Separation

Strand Diameter

Weight

Max. Rated Load

inches

(mm)

lbs/ft

(kg/m)

lbs (kg)

0.109 (2.77)

0.032 (0.048)

1800 (816)

0.134 (3.40)

0.048 (0.075)

2680 (1216)

0.188 (4.77)

0.073 (0.109)

3990 (1810)

0.250 (6.35)

0.121 (0.180)

6650 (3016)

Note: When placing above or between existing plant, match sag.