Cable and Strand Separation

Note: At the time of tensioning the cable and strand must be separated before making permanent attachment.

When a Strand Vise or Strand Grip is used

on IM at dead-end locations, the cable, and

strand must be separated in the web. The web

should be slit to a point 6 inches beyond the

far end of the vise or strand grip.

Note: Do not use a utility knife for slitting the

web on IM Cables.

Remove the poly jacket from the steel and

attach the grip. Make sure the sag is correct

before cutting the excess steel.

Note: It is not necessary to remove the tar

flooding from the steel if present.

Use cable guard or spacers at all

hardware locations.