There is an operating range, though, in between these two extremes of performance that facilitates a dielectric

bond that will cleanly break away from the center conductor without sacrificing the mechanical aspects of the cable.

CommScope has developed, ACT (Advanced Coring

Technology), a patent-pending bonding technology that

operates in this window between the extremes. As shown in

the chart in Figure 1, it exceeds the SCTE requirements for

bond strength and provides for a clean and easy removal of

the bonding material.

With this technology, the force exerted by the coring tool is

sufficient to cause the dielectric to break away from the center

conductor, leaving a clean conductor that typically does not

require a second dielectric removal step. The tool and the

craftsman can influence this enhanced performance

characteristic of the cable, making a one step coring highly

repeatable.

In addition to bond strength, the bonding agent also

maintains the other key performance criteria of the cable as

called out in the SCTE specification. Some of those criteria are

listed in Table 1.

Overall this solution provides all of the benefits of water

migration deterrence, corrosion prevention, and mechanical

performance while eliminating the performance risks

associated with center conductor dielectric removal.

Summary

The bond strength in cable is critical to the mechanical

performance of the cable. However, bonding affects more than

just the cable’s mechanical characteristics, it also impacts the facilitation of cable preparation and

connectorization. Finding the balance of bond strength and craft friendliness is accomplished by the development of an

advanced technology bonding agent and coupling it with CommScope’s consistent manufacturing process controls.

This achievement enables the cable to mechanically behave the way it needs to and makes the preparation easier.

Measure

Passes SCTE

Requirement

Center Conductor Bond Strength

4

Center Conductor Corrosion

4

Water Penetration

4

Air Transmission

4

Dielectric Shrink Back

4

Velocity of Propagation

4

Attenuation

4

TABLE 1 – CABLE PERFORMANCE WITH ACT.