Splicing

Separating Cable and Strand

Measure from the clamp center bolt out 24 inches plus the width of the device plus another 24 inches beyond

the device. Mark the cable at these locations for separation. Consult your company methods and procedures for

equipment placement prior to installation.

Use the appropriate size web slitting tool to separate the steel and cable.

Note: 6” straight cable behind connector

Note: 12” to bend

Note: 24” without expansion loop

Temporarily hang the device on the strand and cut the cable center of the device or if the device location was

marked cut in the center.

Note: Do not remove any cable at this time.

Expansion loops are optional. An expansion loop will provide excess cable for future terminations.

Separation for Splice