AR/GE/FE/U 80/80X Installation Manual 

580­00519 rev. D 

2.6  Cabling 

The installation site should be inspected to determine the run paths for the fiber cable and power 
cable from the radio equipment to the termination point. Locations for roof penetration should be 
identified. The routing and securing of all cables should conform to all applicable codes and 
requirements. Depending on the likelihood of damage due to foot traffic or equipment movement, 
cabling conduit may be required. The maximum cable run length as specified for the equipment 
being installed must not be exceeded, refer to Table 2.6­1 and 2.6­2 for cable types and limitations. 
The radio requires LC type connectors on duplex multi­mode fibers to properly connect between the 
radio and the users network equipment.  Single­mode fiber connections are not supported for use 
with the standard product. The network equipment end of the fibers should be terminated with 
connectors that match the user’s network equipment fiber interface. 

Table 2.6­1: Maximum Fiber Length 

Fiber Cable Length 

Cable Type 

Up to 270 meters 

62.5/125 μm 

Up to 500 meters 

50/125 μm 

The 80GHz radio includes a 100­240 VAC power adaptor, suitable for indoor operation only, that 
converts the AC voltage from a standard electrical outlet in the wall to DC voltage.  For outdoor­ 
rated power supply options, contact BridgeWave customer service. The radio requires a minimum of 
15.0 VDC at the connector on the radio unit (24.0 VDC maximum) to function properly. 

When planning the cable run from the indoor AC power adaptor to the radio unit, it is required to use 
the cable gauge (AWG) indicated below to ensure adequate voltage at the radio.  The indoor and 
outdoor portions of the DC power cabling must conform to all respective indoor and outdoor 
national and local electrical and building codes; note that requirements may differ for the indoor and 
outdoor portions of the cabling and that a grounded surge protector is normally required at the point 
where the cable enters the building.  The DC power cabling must consist of two 12 or 14 gauge­ 
stranded conductors based on the required cable run length. 

Table 2.6­2: Minimum DC Cable Size 

DC Cable Length 

Conductor Size 

Up to 125 meters 

14 AWG 

(2.5mm²) 

Up to 200 meters 

12 AWG 

(4mm²) 

Figure 2.6­1 shows a standard 14­gauge wire that has been fitted with the power connectors 
(provided) for the radio’s internal power supply necessary to mate with the (not provided) DC power