AR/GE/FE/U 80/80X Installation Manual 

27 

580­00519 rev. D 

If you do not obtain a Quality voltage of 2VDC, do not proceed to 
calibrate the system. Ensure you are aligned and achieve your 
target RSL level. This can be confirmed for your path distance by 
looking up the RSL voltage to distance curve in Appendix B. 

4.  At this point you need to connect the fiber cable (or a fiber loopback if no network gear is 

terminated to the far end of the fiber). 

If using a fiber loopback, remove immediately when the Link LED starts blinking. 

Calibrate one side at a time and while monitoring the Quality voltage with DVM. Verify you are 
getting a 'quadruple hump'. i.e. voltage will rise, drop, rise, drop, and rise again, as illustrated below. 
It should end with a 3.0VDC to 3.3VDC reading on your DVM. Also verify the radio ‘Link LED’ is 
also ‘flashing’ on/off during this process. See Figure 3.10.1­1 for an illustration of the Quality 
Voltage as it fluctuates during the calibration process. 

Radio Link LED 

stops flashing 

2.0 ­ 3.3VDC 

Cal

ibr

at

ing

 1

00

0

M

bp

s

 m

od

10 sec. 

C

alib

ra

ting

 1

00

M

bp

s

 m

od

1V 

2

V

 

3V 

3

.3

V

 

Fiber  connected, Radio Link 

LED starts flashing 

Quality Voltage during Calibration Process (90­120 sec.) 

Figure 3.10.1­1:  Quality Voltage reading during Auto Calibration process 

If you cannot obtain a good quality voltage and you have obtained the target RSL, contact Technical 
Support at (408) 567­6906 or e­mail [email protected] for further assistance. 

You must wait for the Auto Calibration process to complete on one 
radio terminal before auto calibrating the remote radio and 
ensure both radios pass the calibration process. Failure to wait 
for the calibration to complete may result in a failure to create an 
RF connection between radio terminals.