AR/GE/FE/U 80/80X Installation Manual 

28 

580­00519 rev. D 

At this point, open the Status page from the unit’s NMS interface and ensure the Radio TX and RX 
is operating at 1000 Mbps for both radios. 

Click the refresh button a few times to ensure it is a good reading. 
If all indicators are good, then go to the next steps. If not, then go 
back to step 1 or contact BridgeWave Technical Support for 
assistance.
 

5. 

Go to Statistics page and reset the stats for each radio end. 

6. 

Perform a ping test. Open two command line windows and ping the local and remote 
management agent. Factory default IPs are; 192.168.0.1 for low­band and 192.168.0.2 for 
high­band and perform a ping to both ends and wait a few minutes, ensure you are getting 
responses from the local and remote management agents. 

7. 

Review statistics page results and ensure packets are being transmitted, received, and there 
are no excessive error conditions. 

8. 

If all is performing well, you must now 'disable' the Installation­Auto Calibration option on 
the Setup page of each radio. 

3.10.2  Installation Auto­Calibration Feature (AdaptRate™ models only): 

This feature should be disabled only after the radio system has been completely installed and 
calibrated as described above. 
In the NMS ‘Setup’ screen, select Installation Auto­Calibration to ‘Disable’ and press the ‘Submit 
new Values button at the bottom of the screen 

Figure 3.10.2­1: 

Installation Auto­Calibration Setting 

(AUTO CALIBRATION FINISHED)