AR/GE/FE/U 80/80X Installation Manual 

35 

580­00519 rev. D 

Antennas aligned on side lobes 

Repeat antenna alignment 
procedure. 

Radios set to different 
polarizations 

Verify that both radios are 
mounted in the same 
polarization. (see section 3.6) 

Installed two high or two low 
band radios in one link 

Verify that one end of the link is 
high and the other end is a low 
band radio 

Test cable not inserted into test 
port on radio properly 

Ensure test cable is completed 
inserted into the test port of the 
radio. 

Make sure that you are using 
correct RSL voltage table. 

If table is for a different product, 
consult the correct product 
manual. 

Low link quality voltage 

Antennas are not aligned for 
maximum RSL 

Verify antenna alignment, use 
instructions provided in sections 
3.6­3.9 

Auto calibration not successfully 
completed 

Repeat auto­calibration 
procedure. 

Interference 

This is unusual unless other 
radios using the same spectrum 
are co­located. 
Check for possible interference 
by turning off the radio at the 
other end of the link and verify 
the RSL voltage on the local 
site drops below 0.2V . 

Test cable not inserted into test 
port on radio properly 

Ensure test cable is completely 
inserted into the test port of the 
radio. 

Cannot connect to radio 
network management agent 

Incorrect IP address 
configuration on radio or PC 

Verify Ethernet connections are 
up, verify IP address, check for 
IP address conflicts, clear ARP 
cache on PC, and/or perform 
hard reset on radio unit (see 
NMS manual). 

Management agent access is 
blocked through one or more 
interfaces 

Verify management access 
configuration on Setup t, and 
change if necessary. Try 
accessing agent through other 
interfaces (fiber, copper, radio 
link)