AR/GE/FE/U 80/80X Installation Manual 

17 

580­00519 rev. D 

A ­48Volt DC version is available for this product. The power 
connector is the same but the connector location is slightly moved. 
The NMS ’Status Page’ reading will still read 24V. 

Figure 3.7.2­1:  80GHz  power and data cables with 
service loop for strain relief and proper fiber bend 
radius. 

3.7.3  Ground Cabling 

The preferred method for grounding the radio unit is to ground the mast to a ground source, since 
this provides the largest grounding surface contact possible. If this is not possible, then use the 
following procedure: 

1. 

Attach the lug of the ground cable (not provided) with the radio to one of the two #8 
holes at the bottom of the radio using a #8­32 x ½” long bolt, #8 lock washer and #8 flat 
washers (not provided). 

2. 

Connect other end of the ground cable to a nearby ground location. 

3.7.4  10/100Base­T Surge Suppressor 

If the 10/100Base­T port is permanently connected to other network equipment (not normally 
required), it should be connected using Cat5e UTP cables rated for the outdoor and/or indoor 
environments where the cables will be run. 
It is essential that the cabling be connected to the radio unit through an Ethernet­rated surge 
suppressor inside of the plastic back cover of the unit, and a surge suppressor should also be used at 
the point where the cable enters a building or is connected to other outdoor equipment that does not 
already contain surge suppression hardware.