AR/GE/FE/U 80/80X Installation Manual 

580­00519 rev. D 

cables. A standard crimping/splicing tool (not provided) is required to terminate the power 
connectors onto a 14­12­gauge cable required for use with the 80GHz. 
On the radio end no connectors are required; simply screw terminals to appropriate polarity. The DC 
power cable should be fed into the connector on the casing first and then the green connector 
attached to the radio after making a strain relief coil around the electronic housing. 

Figure 2.6­1:  (Left) 14­gauge DC power cable terminated to radio end. (Right) DC 14­gauge cable from the power 

supply end. 

2.7  Grounding & Lightning 

Proper grounding of the outdoor equipment reduces 
electromagnetic interference, provides lightning protection, and 
protects against electrical discharge. 
Using improper techniques in lightning prone geographic areas 
may pose a danger to local personnel. 
The source and connection points for the building­to­earth ground 
in the vicinity of the antenna location should be determined.
 

In addition to grounding the equipment, BridgeWave strongly recommends, and local building 
codes may require, the DC electrical cable to be protected from electrical surges by a surge 
suppressor. The surge suppressor must be installed at the point where the DC electrical cables 
exit/enter the building.