Icnc xt – Tweco iCNC XT User Manual
Page 27
iCNC XT
Manual 0-5299
INSTALLATION
3-7
8. Put the grounding clip around the cable shield and screw it back to the amplifier. Add the motor cable ground wire (green/yellow) to the
screw terminal next to the grounding clip.
9. Connect the encoder cable
10. Pull excess cable from the inside of the XT CNC and compile the cable gland. Put the cable gland seal to the cable gland.
11. Press the cable gland through the hole and tighten the nut.
12. Repeat the steps for all axes.
Connecting external voltage supply to the Yaskawa servo amplifiers, 110VAC and 220VAC systems
1. Make sure power is disconnected.
2. Route your power cable through the strain relief..
3. Locate the Yaskawa power filter on the right hand wall inside the XT CNC.
4. Crimp the provided abico connectors to the power cable wires.
5. Push the wires in place to the filter