Icnc xt – Tweco iCNC XT User Manual

Page 94

Advertising
background image

iCNC XT

5-36

OPERATION

Manual 0-5299

Note:

It is not necessary to use all three fi elds to set the database e.g. use material and thickness only and leave tool at Default.

Setting up the Database

A. Click inside the Add/Remove box to activate the “New” box and allow editing. Click New for Material and a new material dialog box

opens. Click on Other then OK. Type in your description for Material, then OK. Repeat steps for Thickness and Tool.

B. Select the wanted material, thickness and tool and enter all correct corresponding values for cutting speed, kerf, pierce height, pierce

time, etc. Review the entire screen making sure each fi eld is correct, then click on the save button and enter the password to lock it
in.

C. Repeat steps A & B to re-enter new parameter settings for new material, thickness and tool.

5.13.2. Aux. Parameters

This parameter fi le contains three parameters. Two frequently changed, user defi ned delays and the part scaling percentage.

Delay nr1: Select the delay from the drop down menu that you will most frequently adjust .

Delay nr2: Select a second delay from the drop down menu that you will adjust frequently.

Note: These two delays will then be displayed in the 1 Parameters and Parameter Quick View windows under the description which was assigned
to them for quick adjustment. These values are usually frequently altered by the user and therefore assigned.

Scale %: This parameter allows the part to be scaled larger or smaller than the size originally created. 100 percent is the actual size as created.
A scale factor of 200 doubles the size. A scale factor of 50 will reduce the size by half. If a part is scaled a message window will appear stating
that the scale is not at 100 percent before running the part.

Advertising